Microfabrication for
Neural Interfaces
and Implants
At Nanosystems JP Inc., we fabricate thin-film neural interfaces to your design: glass microelectrode arrays, silicon neural probes and flexible polyimide electrode arrays. Platinum and gold electrodes by lift-off, iridium oxide and TiN electrode coatings, polymer and inorganic insulation, probe outlines by DRIE or laser, and glass feedthrough parts for device packages. 4 to 12 inch wafers and glass panels, from one wafer.
- Substrate: glass, silicon, polyimide
- Conductor: Ti/Pt or Ti/Au
- Insulation: polyimide, SU-8, SiN
- Electrode surface: Pt, TiN, IrOx
- Bond pad: gold
glass, silicon, polyimide
to 500 × 600 mm
without wet metal etch
no lot minimum
Fabrication to your design and material specification
We build the layers you specify and report the inspection data agreed in the quotation. Materials named on this page are candidate materials: biocompatibility evaluation, sterilization validation and regulatory work are defined in your device program and remain with the device developer.
Thin-film electrodes, insulation and outline,
built as one device
A neural interface is a stack of a few thin films: a conductor that carries the signal, an insulator that confines it, and an electrode surface that meets tissue or culture medium. We fabricate that stack on glass, silicon or polyimide and deliver wafers, diced chips or released flexible devices for your assembly and electrochemical test.
Noble-Metal Electrodes by Lift-Off
Platinum, gold and iridium resist the etchants that pattern ordinary metals, and the thin adhesion layer beneath them is easily undercut. Lift-off avoids both problems: the resist is patterned first, the metal stack is deposited by sputtering or e-beam evaporation, and the resist is dissolved. Electrode sites, tracks and bond pads are defined in one step, and no etchant touches the electrode surface.
Insulation That Defines the Electrode
The opening in the top insulation sets the exposed area of every electrode, so its size and position matter as much as the metal beneath. Polyimide and SU-8 are patterned by photolithography; PECVD SiO₂ and SiN and ALD Al₂O₃ are opened by dry etching. Openings for recording sites and bond pads are aligned to the metal layer.
Electrode Surfaces for Recording and Stimulation
The surface material governs the impedance of a recording site and the charge a stimulation site can deliver. Available surfaces include sputtered platinum, titanium nitride by reactive sputtering, and sputtered iridium oxide film (SIROF), deposited on the electrode sites only. Impedance and charge-injection targets come from your design and are confirmed in your electrochemical test.
Glass, silicon and polyimide,
matched to where the device works
The same thin-film stack is built on three substrate platforms. Glass serves in-vitro arrays that are viewed through a microscope, silicon gives rigid penetrating probes with lithographic precision, and polyimide gives thin arrays that conform to tissue. Our engineers review your layout and recommend the route for your geometry and quantity.
Planar Microelectrode Arrays on Glass
Illustration, not to scale. Array layout with contact pads on four edges; the inset shows four sites with their insulation openings.
Arrays of electrode sites on borosilicate glass or fused silica for extracellular recording and stimulation of cultured neurons, cardiomyocytes, brain slices and organoids. Tracks and contact pads in Ti/Au or Ti/Pt are patterned by lift-off, and an SU-8 or polyimide layer is opened at the recording sites. Transparent ITO electrodes and tracks are available where the culture is imaged through the array.
Glass is processed as wafers or as large panels, and chip formats from small research dies to full-size culture plates are laid out and diced to your drawing.
Silicon Neural Probes
Illustration, not to scale. Four-shank probe with bond pads on the base; the inset shows sites and tracks at a shank tip.
Single-shank and multi-shank probes with electrode sites along each shank and bond pads on the base. Metal and insulation are patterned on the wafer front, then deep reactive ion etching cuts the probe outline. On SOI wafers the device layer sets the shank thickness and the buried oxide stops the etch, so thickness is fixed by the wafer rather than by etch time.
Probes are released by backside etching or by thinning on a carrier, and the delivery format is agreed for your handling and assembly.
Flexible Thin-Film Arrays on Polyimide
Illustration, not to scale. Electrode grid, ribbon cable and connector tab made in the same polyimide and metal layers.
Thin electrode arrays in which the metal runs between two polyimide layers, for cortical surface grids, peripheral nerve interfaces, retinal arrays and the ribbon cables that connect them. The device is built flat on a rigid carrier with the same lithography, lift-off and deposition used on wafers, and is separated from the carrier at the end.
Two routes are available, chosen by device thickness, feature size and area:
Spin-On Polyimide on a Carrier Wafer
Liquid polyimide is spin-coated and cured on a carrier wafer, the metal layer is patterned on it, and a second polyimide layer is added and opened at the sites and pads. The outline is cut by dry etching or laser and the devices are released from the carrier. The usual route for thin devices with fine features.
Polyimide Film on a Carrier
Polyimide film of 12.5 to 125 µm is mounted flat on a carrier, patterned by photolithography, PVD and lift-off, insulated, and trimmed to outline by laser. The route for larger arrays, connector tails and sensor patches where a thicker, more robust film is wanted. See PI film and SUS sensor fabrication.
| Parameter | Glass microelectrode array | Silicon neural probe | Flexible polyimide array |
|---|---|---|---|
| Substrate | Borosilicate glass or fused silica, as wafers or panels | Silicon or SOI wafers | Spin-on polyimide on a carrier wafer, or polyimide film of 12.5 to 125 µm |
| Conductor | Ti/Au, Ti/Pt, ITO | Ti/Au, Ti/Pt | Ti/Au, Ti/Pt |
| Insulation | SU-8, polyimide, PECVD SiO₂ or SiN | PECVD SiO₂ or SiN, polyimide, ALD Al₂O₃ | Polyimide, with ALD or PECVD barrier layers on request |
| Outline | Blade, laser or stealth dicing | DRIE through the device layer, then backside release | Dry etch or laser, then release from the carrier |
| Typical use | In-vitro recording and stimulation | Acute and chronic research probes | Surface grids, nerve interfaces, cables |
| Biocompatibility | Candidate materials on every platform; biocompatibility is evaluated per program by the device developer | ||
Six steps from substrate
to released device
The sequence is the same on glass, silicon and polyimide. What changes is the base layer under the metal and the way the finished device leaves the wafer or carrier.
Substrate and base layer
Glass, silicon with thermal oxide or nitride, or a first polyimide layer on a carrier.
Metal lift-off
Resist pattern, Ti/Pt or Ti/Au deposition, lift-off: sites, tracks and pads in one layer.
Insulation
Polyimide, SU-8, or a PECVD or ALD film covers the tracks.
Site and pad opening
Photolithography or dry etching opens the electrode sites and bond pads.
Site coating, optional
Pt, TiN or iridium oxide is deposited on the electrode sites only.
Outline and release
DRIE, laser or dicing defines the outline; devices leave the wafer or carrier and are inspected.
Schematic cross-sections, not to scale. The steps and their order are fixed in the process flow agreed for your device.
Platinum, gold, iridium oxide and TiN,
chosen for the job each site does
Recording sites, stimulation sites, tracks and bond pads ask different things of a metal. The stack is specified layer by layer, deposited by sputtering or e-beam evaporation, and patterned by lift-off.
Polymer and inorganic films,
alone or in combination
Insulation carries the mechanical load in a flexible device and keeps moisture and ions away from the tracks in every device. Polymers give thickness and flexibility; thin inorganic films add a dense barrier. The combination is chosen for your environment and service-life target, and its long-term behavior is established in your soak or implant testing.
Polyimide
Spin-coated, patterned by photolithography and cured at 300 to 350 °C, or opened by reactive ion etching. Polyimide is the base and top layer of flexible arrays and a passivation layer on glass and silicon. Polymer grades for medical-device programs are selected at design review.
SU-8
A permanent epoxy layer patterned by photolithography in thicknesses from 5 µm to over 500 µm. SU-8 is a common insulation for glass microelectrode arrays, and the same material builds culture wells, guides and microfluidic walls on top of the electrodes.
Inorganic Barrier Films
PECVD SiO₂, SiN and SiON at 150 to 400 °C, with routes at 150 to 200 °C for polymer surfaces, and ALD Al₂O₃, HfO₂ and TiO₂ from 1 to 300 nm as a conformal moisture barrier. Openings are dry-etched. These films are used alone on silicon probes or as a thin barrier between polymer layers.
From patterned wafer
to individual probes and arrays
A neural device is rarely a rectangle. Shanks taper to a tip, flexible arrays carry long tails, and both must leave the wafer without damage to the electrode surface.
Silicon Probes: DRIE on SOI
The probe outline is etched by the Bosch process with sidewalls at 89° to 90°. On SOI the etch stops on the buried oxide, so the device layer, from 2 to 200 µm, fixes the shank thickness across the wafer. The handle silicon under the probes is then removed by backside etching aligned to the front, or the wafer is thinned on a carrier to 50 to 100 µm. Retaining tabs drawn in your layout hold the probes until pick-up.
Flexible Arrays and Glass Chips: Dry Etch, Laser and Dicing
Polyimide is cut to outline by reactive ion etching through a mask or by laser, which also opens connector windows and anchoring holes drawn in your layout. The devices are then released from the carrier and inspected. Glass and silicon chips are separated by blade, laser or stealth dicing: stealth dicing is a dry process, and laser cutting gives non-rectangular outlines.
Glass feedthroughs, cap wafers
and the connection to the electronics
An implanted electrode array is only as durable as the package behind it. The same program can supply wafer-level parts of that package: feedthrough substrates, cap wafers and glass bonding steps. The package design, its assembly and its qualification stay with your program.
- Flexible electrode array: polyimide, metal, polyimide
- Glass feedthrough substrate with through-glass vias (TGV)
- Bond line: anodic bond or patterned metal seal frame
- Cap with etched cavity, glass or silicon
- Electronics inside the cavity (your die)
- Gold bumps or bond pads
Illustration of one possible package architecture, not to scale. The architecture, via metal and pad finish are reviewed per program; leak or hermeticity testing is agreed separately.
Glass Feedthroughs and Caps
Through-glass vias from 20 µm in diameter, in borosilicate glass or fused silica, for feedthrough designs in glass packages; the via metal and the fill are reviewed against your design. Cavity caps in glass or silicon are joined by anodic bonding of borosilicate glass to silicon at 300 to 450 °C, or carry patterned metal seal frames. Leak or hermeticity testing is agreed separately. See wafer-level fabrication for implantable devices.
Pads and Bumps for Your Assembly
Gold bond pads for wire bonding, and gold bumps for thermocompression or thermosonic attach of a flexible array or a die. Gold-to-gold joints serve where solder metallurgy is excluded by the application. Assembly steps are reviewed per program.
Capability ranges for
neural interface fabrication
| Parameter | Capability | Notes |
|---|---|---|
| Substrates | Borosilicate glass, fused silica, silicon, SOI, spin-on polyimide, polyimide film (12.5 to 125 µm) | As wafers or glass panels |
| Conductor stacks | Ti/Pt: 10 to 30 nm Ti / 50 to 200 nm Pt. Ti/Au: 10 to 50 nm Ti / 50 to 500 nm Au | Typical lift-off thicknesses; thicker by electroplating |
| Electrode surfaces | Pt, Ir, sputtered iridium oxide (SIROF), TiN, ITO | Thickness per design |
| Metal patterning | Lift-off, features below 2 µm on wafers | Design rules confirmed at review |
| Lithography | Mask aligner from 4 µm, front-to-back alignment; stepper and e-beam for finer features | 3 µm line and space on polymer film |
| Polymer insulation | Polyimide cured at 300 to 350 °C; SU-8 from 5 µm to over 500 µm | Openings by photolithography or RIE |
| Inorganic insulation | PECVD SiO₂, SiN, SiON: 50 nm to 5 µm at 150 to 400 °C. ALD Al₂O₃, HfO₂, TiO₂: 1 to 300 nm at 80 to 300 °C | PECVD at 150 to 200 °C on polymers |
| Silicon outline | Bosch DRIE, 89° to 90° sidewalls, aspect ratio above 50:1 on narrow features; SOI device layer 2 to 200 µm | Through-wafer release |
| Flexible outline | RIE of polyimide or laser, then release from the carrier | Release agreed per program |
| Thinning | 50 to 100 µm on a carrier; 150 to 300 µm free-standing | Thinner on inquiry |
| Singulation | Blade, laser and stealth dicing; die size from about 0.3 mm | Non-rectangular outlines by laser |
| Package parts | TGV from 20 µm in borosilicate glass or fused silica; anodic bonding at 300 to 450 °C (4 to 8 inch); patterned metal seal frames | Leak test agreed separately |
| Pads and bumps | Gold bond pads, gold bumps, ENEPIG pad finish | Assembly steps reviewed per program |
| Biocompatibility | Candidate materials, evaluated per program | Evaluation and regulatory work by the device developer |
| Minimum lot | From 1 wafer | Prototype and pilot lots |
Ranges are taken from the linked process pages, and the available wafer or panel size depends on the process sequence. The figures for your device are confirmed in the quotation after engineering review.
Neural interfaces from the culture dish
to the implant
In-Vitro Microelectrode Arrays
Planar MEAs on glass for extracellular recording and stimulation of neuronal cultures, brain slices, cardiomyocytes and organoids, and for drug-response screening. Pt, Au or TiN sites with SU-8 or polyimide insulation, and ITO where the culture is imaged from below.
Silicon Probes for Neuroscience
Single-shank and multi-shank silicon probes for acute and chronic recording in research animals, with sites distributed along the shank for recording across cortical layers.
Cortical Surface Grids (ECoG, µECoG)
Thin polyimide electrode grids that conform to the cortical surface, with the connecting ribbon cable made in the same polyimide and metal layers as the array.
Peripheral Nerve Interfaces
Cuff and intraneural electrode layouts in thin polyimide for recording and stimulation of peripheral nerves in prosthetics and bioelectronic medicine research.
Retinal and Cochlear Electrode Arrays
Thin arrays with many small stimulation sites for retinal and cochlear implant development, where iridium oxide surfaces are commonly specified for charge delivery through a small electrode.
Neurochemical and Biosensor Electrodes
Pt, Au and glassy carbon electrodes for electrochemical detection, on glass, silicon or flexible substrates, with openings that define the active electrode area.
Brain-on-Chip and Organoid Platforms
Electrode arrays combined with microfluidic channels, wells and bonded covers for organ-on-chip and organoid electrophysiology. See biochip and microfluidics.
Implant Package Components
Glass feedthrough substrates with TGV, cavity caps, anodic bonding and patterned metal seal frames for the electronics housings of implantable devices. See wafer-level fabrication for implantable devices.
Wearable and Skin-Contact Electrodes
Electrode arrays and biosensor structures on polyimide film for skin-contact and wearable sensing, where the substrate must conform to the body. See PI film and SUS sensor fabrication.
What makes our neural interface
fabrication different
Nanosystems JP Inc. is a pure-play MEMS and semiconductor foundry based in Tokyo, Japan. We fabricate to your design, for companies and university laboratories worldwide.
Glass, silicon and polyimide in one program
Rigid arrays, penetrating probes and flexible arrays share the same lithography, lift-off and deposition steps. Your device family is managed end to end by a dedicated project manager, whichever substrate each part needs.
Noble metals patterned by lift-off
Pt, Au and their adhesion layers are defined by the resist, not by an etchant, so the electrode surface stays clean and the adhesion layer is not undercut. Lift-off features below 2 µm are available on wafers.
Electrode coatings in the same flow
Sputtered iridium oxide, TiN and platinum are added to the opened sites as part of the same process flow, so the coating is aligned to the opening it has to fill.
Polymer and inorganic insulation
Polyimide and SU-8 are combined with PECVD and ALD barrier films layer by layer, with low-temperature routes for films that go on top of polymers.
Package parts in the same program
Through-glass vias, cap wafers, anodic bonding and gold bumps continue from the electrode wafer under the same project manager.
From 1 wafer, no minimum lot
Prototype on a single wafer, test the electrodes in your own setup, then repeat the recipe for pilot lots. The prototype data becomes the baseline for repeat builds.
Thin-film metal, UBM and AuSn pads on polyimide for chip attach, glass through-vias for feedthrough designs, and daisy-chain bonding test wafers.
Start your project.
Initial response typically within one business day.
Share your device type, substrate and quantity. A Nanosystems JP Inc. engineer gives an initial response, typically within one business day. A written quotation typically follows within 7-10 business days after we receive the required information and complete any prerequisite NDA.
- Device type and substrate
- Electrode count, site size and pitch
- Metal, insulation and site coating
- Outline drawing or GDS, if available
- Intended use: in vitro, animal research or clinical development
- Quantity and target date